Old Keyword
|
New Keyword
|
Notes
|
|---|
|
Buffers
|
Buffers[x].Num where x = 0
|
|
|
|
BufferSize
|
Buffers[x].Size where x = 0
|
|
|
|
CallSetupPool
|
DSP.C5x[x].CallSetupPool
|
[dsp0[..dspn]] = value
Where x = the DSP number specified in ag.cfg. If a DSP number is not specified, then x = all DSPs [0..7].
|
|
CallSetupPorts
|
CallSetupPorts
|
|
|
CCMode
|
CCMode
|
|
|
ClockRef
|
Clocking.HBus.ClockSource
|
AG
OSC
H100
SEC8K
NET1
NET2
NET3
NET4
MVIP
|
OAM
OSC
A_CLOCK
NETREF
NETWORK
NETWORK
NETWORK
NETWORK
C4
|
|
|
Clocking.HBus.ClockSourceNetwork
|
If ClockRef was set to NETx, set this keyword = x.
|
|
ConnectMode
|
SwitchConnectMode
|
AG
FRAMED
UNFRAMED
|
OAM
AllConstantDelay
AllDirect
|
|
D_channel
|
NetworkInterface.T1E1[x].D_Channel
|
If DigitalMode = PRI, set NetworkInterface.T1E1[x]. D_Channel = ISDN.
If DigitalMode = RAW, set NetworkInterface.T1E1[x]. D_Channel = ISDN_NONE.
|
|
Diagnostics
|
BootDiagnosticLevel
|
|
|
DigitalMode
|
NetworkInterface.T1E1[x].SignalingType
|
x is the trunk number.
|
|
DriveSec8K
|
Clocking.HBus.NetRefSource
Clocking.HBus.NetRefSourceNetwork
|
If DriveSec8K = OSC, set Clocking.HBus.NetRefSource = OSC.
If DriveSec8K is set to any other value, set Clocking.HBus.NetRefSource = NETWORK.
If DriveSec8K = NET1, NET2, NET3, or NET4, then set this keyword to 1, 2, 3, or 4.
Otherwise, do not set this keyword.
|
|
DSP_OS
|
DSP.C5x.Os
|
|
|
DSPfile
|
DSP.C5x.DSPFiles[x]
DSP.C5x[x].Files[y]
|
|
|
|
EnableMVIP
|
Clocking.HBus.ClockMode
|
If there is no EnableMVIP setting in agmon, refer to the ClockRef value. If ClockRef is equal to either H100 or MVIP, set Clocking.HBus.ClockMode = SLAVE. If ClockRef is equal to a value other than H100 or MVIP, set Clocking.HBus.ClockMode = STANDALONE.
If EnableMVIP was set to NO in agmon, set Clocking.HBus.ClockMode = STANDALONE.
If EnableMVIP = YES, determine the ClockRef setting in the ag.cfg file. If the ClockRef setting was H100 or MVIP, set to SLAVE.
If the ClockRef setting was not H100 or MVIP, set to MASTER_A.
There is no migration for the MASTER_B option.
|
|
FrameType
|
NetworkInterface.T1E1[x].FrameType
|
Use the value of FrameType in ag.cfg. where x is the trunk number.
A value must be specified even if one was not specified in agmon.
T1 = ESF or D4
E1 = CEPT
|
|
IdleCode
|
SignalIdleCode
VoiceIdleCode
Xlaw
|
If IdleCode = number, use this number for both SignalIdleCode and for VoiceIdleCode. If IdleCode is equal to two numbers, use the first number for VoiceIdleCode and use the second number for SignalIdleCode.
If IdleCode = string, set Xlaw as follows:
|
|
|
|
AG
Mu-LAW
A-LAW
|
OAM
MU-LAW
A-LAW
|
|
Interrupt
|
None
|
|
|
|
LineCode
|
NetworkInterface.T1E1[x].LineCode
|
x = trunk number
A value must be specified even if one was not specified in agmon.
If you have a T1 board and NetworkInterface.T1E1[x]. SignalingType = CAS, set this value to AMI_ZCS.
If you have a T1 board and NetworkInterface.T1E1[x]. SignalingType is not equal to CAS, set this value to B8ZS.
If you have an E1 board, set this value to HDB3.
|
|
LineLength
|
NetworkInterface.T1E1[x].Length
|
Use the value of LineLength in ag.cfg where x is the trunk number. Do not generate a default if a LineLength was not specified.
|
|
LoadFile
|
LoadFile
|
|
|
|
MaxChannels
|
MaxChannels
|
|
|
|
MedBuffers
|
Buffers[x].Num where x = 1
|
|
|
|
MedBufferSize
|
Buffers[x].Size where x = 1
|
|
|
|
NAI
|
NetworkInterface.T1E1[x].ISDN.NFAS_MEMBER[y].NAI
|
|
|
|
NFAS_Group
|
NetworkInterface.T1E1[x].ISDN.D_Channel_Backup_Trunk
NetworkInterface.T1E1[x].ISDN.NFAS_MEMBER[y].Board
NetworkInterface.T1E1[x].ISDN.NFAS_MEMBER[y].NAI
NetworkInterface.T1E1[x].ISDN.NFAS_ MEMBER[y].Trunk
NetworkInterface.T1E1[x].ISDN.NFASGroup
|
|
|
PCIbus
|
Location.PCI.Bus
|
|
|
PCIslot
|
Location.PCI.Slot
|
|
|
RunFile
|
RunFile
|
|
|
RunModule
|
DLMFiles[x]
|
|
|
SmallBuffers
|
Buffers[x].Num where x = 2
|
|
|
|
TaskProcessor
|
DSP.C5x[x].Files[y]
DSP.C5x[x].Limits[y]
DSP.C5x[x].TaskListSize
|
If a DSP processor range is specified, then it converts to x. Otherwise, it applies to all processors (from 0 to number of DSPs).
If the limit is specifed (there is a prepended +), then set that value in the DSP.C5x[x].Limits[y] keyword. If a limit is not specified, do not enter a value in this keyword.
If the size is specified (has a prepended -), set that value in the DSP.C5x[x].TaskListSize keyword.
|
|
TCP
|