Table of Contents Index NMS Glossary Previous Page Next Page (Page 15 of 81 in this chapter) Version


Clocking.HBus.FallBackNetwork

For information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to Section 3.5, Configuring Board Clocking.

Syntax

Clocking.HBus.FallBackNetwork = network_number

Access

Read/Write

Type

Integer

Default

1

Allowed Values

1 | 2 | 3 | 4

Example

Clocking.HBus.FallBackNetwork = 1

Description

Specifies the number of the digital trunk to use as an external network timing reference if the clock source defined with Clocking.HBus.ClockSource fails.

The board must have multiple external network connections and the Clocking.HBus.FallBackClockSource keyword must be set to NETWORK for this to take effect.
Caution:

The Clocking.HBus.FallBackNetwork entry is a one based number, while the x entry in the NetworkInterface.T1E1[x].Type keyword is a zero based number.


For more information about clock fallback, refer to the Switching Service Developer's Reference Manual.

Note: If you want to support clock fallback on an AG board, refer to the NMS web site (www.nmss.com) for more information.

See Also

Clocking.HBus.AutoFallBack, Clocking.HBus.ClockSource, Clocking.HBus.FallBackClockSource



Table of Contents Index NMS Glossary Previous Page Next Page (Page 15 of 81 in this chapter) Version