Clocking.HBus.NetRefSource

For information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to Section 3.5, Configuring Board Clocking.

Syntax

Clocking.HBus.NetRefSource = source

Access

Read/Write

Type

String

Default

STANDALONE

Allowed Values

OSC | NETWORK | STANDALONE

Example

Clocking.HBus.NetRefSource = NETWORK

Description

Specifies a source to drive the NETREF timing signal on the CT bus.
Value

Description

OSC

The oscillator uses the board's local clock (for diagnostics only).

NETWORK

The timing signal is derived from a device source (digital trunk). When using this keyword, you must also specify the trunk number with Clocking.HBus.NetRefSourceNetwork.

STANDALONE

The NETREF clock is not driven.

If you set this keyword to NETWORK, you must also specify a timing source with the Clocking.HBus.NetRefSourceNetwork keyword.

See Also

Clocking.HBus.NetRefSourceNetwork, Clocking.HBus.NetRefSpeed