(Page 14 of 80 in this chapter)
Version
Clocking.HBus.NetRef2Source
For information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to
Section 3.5, Configuring Board Clocking
.
Syntax
Clocking.HBus.NetRef2Source =
source
Access
Read/Write
Type
String
Default
STANDALONE
Allowed Values
OSC
|
NETWORK
|
STANDALONE
Example
Clocking.HBus.NetRef2Source = NETWORK
Description
Specifies the source to drive the
NETREF2
timing signal on the CT bus.
Value
Description
OSC
The oscillator uses the board's local clock (for diagnostics only)
NETWORK
The clock signal is derived from a device source (digital trunk). When using this keyword, you must also specify the trunk number with
Clocking.HBus.NetRef2SourceNetwork
.
STANDALONE
The
NETREF2
timing signal is not driven
If this keyword is set to
NETWORK
, you must also specify a value with the
Clocking.HBus.NetRef2SourceNetwork
keyword.
See Also
Clocking.HBus.NetRef2SourceNetwork
,
Clocking.HBus.NetRef2Speed
(Page 14 of 80 in this chapter)
Version
Want to send us feedback on our documentation? Email:
Tech_Pubs@nmss.com