Table of Contents Index NMS Glossary Previous Page Next Page (Page 14 of 80 in this chapter) Version


Clocking.HBus.NetRef2Source

For information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to Section 3.5, Configuring Board Clocking.

Syntax

Clocking.HBus.NetRef2Source = source

Access

Read/Write

Type

String

Default

STANDALONE

Allowed Values

OSC | NETWORK | STANDALONE

Example

Clocking.HBus.NetRef2Source = NETWORK

Description

Specifies the source to drive the NETREF2 timing signal on the CT bus.
Value

Description

OSC

The oscillator uses the board's local clock (for diagnostics only)

NETWORK

The clock signal is derived from a device source (digital trunk). When using this keyword, you must also specify the trunk number with Clocking.HBus.NetRef2SourceNetwork.

STANDALONE

The NETREF2 timing signal is not driven

If this keyword is set to NETWORK, you must also specify a value with the Clocking.HBus.NetRef2SourceNetwork keyword.

See Also

Clocking.HBus.NetRef2SourceNetwork, Clocking.HBus.NetRef2Speed



Table of Contents Index NMS Glossary Previous Page Next Page (Page 14 of 80 in this chapter) Version