Clocking.HBus.NetRef2SourceNetwork

For information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to Section 3.5, Configuring Board Clocking.

Syntax

Clocking.HBus.NetRef2SourceNetwork = network_number

Access

Read/Write

Type

Integer

Default

1

Allowed Values

1 | 2 | 3 | 4

Example

Clocking.HBus.NetRef2SourceNetwork = 2

Description

Specifies the number of the trunk used to drive the NETREF2 timing signal on the CT bus.

You must specify a value to this keyword when the Clocking.HBus.NetRef2Source keyword is set to NETWORK. If the Clocking.HBus.NetRef2Source keyword is not set to NETWORK, this keyword is ignored.

See Also

Clocking.HBus.NetRef2Source, Clocking.HBus.NetRef2Speed