(Page 17 of 80 in this chapter)
Version
Clocking.HBus.NetRefSource
For information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to
Section 3.5, Configuring Board Clocking
.
Syntax
Clocking.HBus.NetRefSource =
source
Access
Read/Write
Type
String
Default
STANDALONE
Allowed Values
OSC
|
NETWORK
|
STANDALONE
Example
Clocking.HBus.NetRefSource
=
NETWORK
Description
Specifies a source to drive the
NETREF
timing signal on the CT bus.
Value
Description
OSC
The oscillator uses the board's local clock (for diagnostics only).
NETWORK
The timing signal is derived from a device source (digital trunk). When using this keyword, you must also specify the trunk number with
Clocking.HBus.NetRefSourceNetwork
.
STANDALONE
The
NETREF
clock is not driven
If you set this keyword to
NETWORK
, you must also specify a timing source with the
Clocking.HBus.NetRefSourceNetwork
keyword.
See Also
Clocking.HBus.NetRefSourceNetwork
,
Clocking.HBus.NetRefSpeed