(Page 18 of 80 in this chapter) Version
Clocking.HBus.NetRefSourceNetwork
- For information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to Section 3.5, Configuring Board Clocking.
Syntax
- Clocking.HBus.NetRefSourceNetwork = network_number
Access
- Read/Write
Type
- Integer
Default
- 1
Allowed Values
- 1 | 2 | 3 | 4
Example
- Clocking.HBus.NetRefSourceNetwork = 1
Description
- Specifies the number of the trunk used to drive the NETREF timing signal on the CT bus.
- You must specify a value with this keyword when the Clocking.HBus.NetRefSource keyword is set to NETWORK. If the Clocking.HBus.NetRefSource keyword is not set to NETWORK, this keyword is ignored.
See Also
- Clocking.HBus.NetRefSource
, Clocking.HBus.NetRefSpeed