Syntax
SwitchConnections =
setting
Access
Read/Write
Type
String
Default
Auto
Allowed Values
Yes | No | Auto
Example
SwitchConnections = Yes
Description
Specifies whether or not to nail up default connections.
Setting
Description
Yes
Nails up connections independent of the
Clocking.HBus.ClockMode
setting.
No
Does not nail up connections.
Auto
Nails up connections automatically if
Clocking.HBus.ClockMode
= Standalone
.
When running the Point-to-Point Switching service, set
SwitchConnections = No
. Use the
ppx.cfg
file to define default connections. For more information, refer to the
Point-to-Point Switching Service Developer's Reference Manual
.