Table of Contents Index NMS Glossary Previous Page Next Page (Page 8 of 40 in this chapter) Version


Clocking.HBus.ClockMode

Syntax

Clocking.HBus.ClockMode = clockmode

Access

Read/Write

Type

String

Default

MASTER_A

Allowed Values

MASTER_A | SLAVE

Example

Clocking.HBus.ClockMode = MASTER_A

Description

This keyword is valid for QX 2000/100-4L boards only. It specifies the board's control of the H.100 clock.

Valid entries for this keyword include:
Value

Description

MASTER_A

The board will serve as clock master, driving the CT bus A clock based on the clocking information derived from the timing references specified with Clocking.HBus.ClockSource

SLAVE

The board will act as a clock slave, deriving its timing from the primary clock master.

Note: Connections are allowed to the board's CT bus timeslots.

For more information about QX board clocking, refer to Chapter 5. For general information about CT bus clocking, refer to the OAM System User's Manual.

See Also

Clocking.HBus.AutoFallBack, Clocking.HBus.ClockSource, Clocking.HBus.FallBackClockSource



Table of Contents Index NMS Glossary Previous Page Next Page (Page 8 of 40 in this chapter) Version


Want to send us feedback on our documentation? Email: Tech_Pubs@nmss.com