Table of Contents Index NMS Glossary Previous Page Next Page (Page 6 of 40 in this chapter) Version


Clocking.Type

For more information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to Chapter 5 - Configuring Board Clocking.

Syntax

Clocking.Type = type

Access

Read-only

Type

String

Allowed Values

Hbus for QX 2000/100-4L boards
MVIP for QX 2000/80-4L boards

Description

Specifies the type of bus to configure the clock on.

See Also

Clocking.HBus.AutoFallBack, Clocking.HBus.ClockMode, Clocking.HBus.ClockSource, Clocking.HBus.FallBackClockSource, Clocking.MVIP.AutoFallBack, Clocking.MVIP.ClockRef, Clocking.MVIP.FallBackClockSource



Table of Contents Index NMS Glossary Previous Page Next Page (Page 6 of 40 in this chapter) Version