(Page 60 of 97 in this chapter) Version
Hdlc[x].RxTimeSlot
Syntax
- Hdlc[x].RxTimeSlot = timeslot
- x = 0...15 (HDLC index)
Access
- Read/Write
Type
- Integer
Default
- 0
Allowed Values
- 0..31 (timeslot or range of timeslots)
Example
- Hdlc[0...15].RxTimeSlot = 16
Description
- Specify the TDM time slot of the receiving HDLC signal for a specific trunk. The following HDLC signals are associated with CG 6100C trunks:
See Also
- Hdlc[x].Boot
, Hdlc[x].TxTimeSlot