NMS Logo

CG 6100C Installation and Developer's Manual

P/N 9000-60041-13
Version


Table of Contents Index NMS Glossary Previous Page Next Page Version


Table of Contents

1 Overview of the CG 6100C Board

1.1 Introduction
1.2 CG 6100C Board Features
1.2.1 Voice and Fax Support
1.3 Software Requirements
1.3.1 NMS OAM
CG Board Plug-In
1.3.2 OAM Configuration Files
1.3.3 Runtime Software
1.3.4 Trunk Control Programs (TCPs)
1.3.5 Natural Access

2 Installing the Hardware

2.1 Introduction
2.2 Installation Summary
2.2.1 CG Driver Software
2.3 System Requirements
2.4 Installing the Hardware
2.4.1 T1/E1 120 Ohm Configuration
2.4.2 E1 75 Ohm Configuration
2.4.3 Sample T1 Trunk Configuration
2.4.4 Sample E1 Trunk Configuration
2.4.5 Keying the Chassis for CG 6100C Boards
2.4.6 Installing the Board
2.5 Trunk Connections
2.6 Connecting a CG 6100C Board to an E1 Network
2.6.1 Connecting a CG 6100C to an E1 120 Ohm
2.6.2 Connecting a CG 6100C to an E1 75 Ohm
Grounding the Conductor
2.7 Connecting a CG 6100C Board to a T1 Network
2.7.1 Connecting a CG 6100C to the T1 Network
2.7.2 Ordering T1 Service
2.8 Loopback Configuration

3 Configuring the Board

3.1 Introduction
3.2 Adding Board Configurations to the NMS OAM Database
3.3 Configuring and Starting the System with oamsys
3.3.1 Creating a System Configuration File for oamsys
Sample System Configuration File
3.3.2 Running oamsys
3.4 Changing Configuration Parameter Settings
3.4.1 Board Keyword Files
3.5 Configuring Board Clocking
3.5.1 Clocking References
3.5.2 Clocking Capabilities
Clocking Capabilities as Primary Master
Clocking Capabilities as Secondary Master
Clocking Capabilities as Slave
Other Clocking Capabilities
3.5.3 Clock Fallback
3.5.4 Configuring CT Bus Clocks with CG Keywords
Configuring the Primary Clock Master
Configuring the Secondary Clock Master
Configuring Clock Slaves
Configuring Standalone Boards
3.5.5 Example: Multiple Board System
3.5.6 NETREF Clocking
3.6 TDM Switch Streams and DSP Physical Layouts
3.7 Sample Board Keyword Files
3.7.1 No Call Control Configuration
3.7.2 Line Interface Configuration
3.7.3 Setting Up Resource Management for Multiple Pools
3.7.4 MFC Protocol for 20 DSP Cores with 16 Trunks
3.7.5 MFC Protocol and Voice for 20 DSP Cores with 8 Trunks
3.7.6 Assigning and Using Pooled Resources
Creating DSP Resource Pools
Implementing a Resource Sharing Algorithm
3.7.7 ISDN Protocol and Voice for 36 DSP Cores with 16 Trunks
3.8 Using DSP Resource Management Keywords
3.8.1 Resource Management Keywords
3.8.2 Resource Definition String Syntax
3.8.3 DSP Files
Example: Configuring Available DSP Resources
3.8.4 Resource Definitions
Example: All DPFs Running Exclusively
Example: All DPFs Execute Simultaneously
3.8.5 Specifying Conditional Relationships Between DSP Functions
Example 1
Example 2
3.8.6 Echo Cancellation

4 Verifying the Installation

4.1 Introduction
4.2 LEDs
4.2.1 Trunk LEDs
4.2.2 Hot Swap LED
4.2.3 Ethernet LEDs
4.3 Verifying That the Board is Installed Correctly
4.4 Verifying That the Board is Working Correctly
4.5 Demonstration Programs

5 CG 6100C Switching

5.1 Introduction
5.1.1 Switch Blocking
5.2 CG 6100C Switch Models
5.2.1 CG 6100C Switch Model: CAS Mode
Voice and Signaling Information Routing on T1 Trunks
(CAS Mode)
Voice and Signaling Information Routing on E1 Trunks
(CAS Mode)
Default Connections (CAS Mode)
5.2.2 CG 6100C Switch Model: PRI Mode
Voice Information Routing on T1 Trunks (PRI Mode)
Voice Information Routing on E1 Trunks (PRI Mode)
T1/E1 Signaling Information Routing (PRI Mode)
Default Connections (PRI Mode)
5.2.3 CG 6100C Switch Model: RAW Mode
Voice Information Routing on T1 Trunks (RAW Mode)
Voice Information Routing on E1 Trunks (RAW Mode)
T1/E1 Signaling Information Routing (RAW Mode)
Default Connections (RAW Mode)

6 CG Keyword Reference

6.1 Introduction
6.2 Keyword Types
6.2.1 Setting Keyword Values
6.2.2 Retrieving Keyword Values
6.3 Summary of Editable Keywords
6.4 Summary of Informational Keywords
6.5 Summary of Plug-in Keywords
6.6 Alphabetical Keyword Reference
AutoStart
AutoStop
Boards[x]
BootDiagnosticLevel
BootDiagnosticMask
Buffer[x].Size
Clocking.HBus.AutoFallBack
Clocking.HBus.ClockMode
Clocking.HBus.ClockSource
Clocking.HBus.ClockSourceNetwork
Clocking.HBus.FallBackClockSource
Clocking.HBus.FallBackNetwork
Clocking.HBus.NetRef2Source
Clocking.HBus.NetRef2SourceNetwork
Clocking.HBus.NetRef2Speed
Clocking.HBus.NetRefSource
Clocking.HBus.NetRefSourceNetwork
Clocking.HBus.NetRefSpeed
Clocking.HBus.SClockSpeed
Clocking.HBus.Segment
DebugMask
DetectedBoards[x]
DLMFiles[x]
Driver.BoardId
Driver.Name
DSP.C5x[x].Files[y]
DSP.C5X[x].Image
DSP.C5x[x].Libs[y]
DSP.C5x[x].NumRxTimeSlots
DSP.C5x[x].NumTxTimeSlots
DSP.C5x[x].Os
DSP.C5x[x].XLaw
DSPStream.SignalIdleCode[x]
DSPStream.SlotCount
DSPStream.VoiceIdleCode[x]
Eeprom.AssemblyRevision
Eeprom.DSPExtClk
Eeprom.DSPSpeed
Eeprom.DSPType
Eeprom.Family
Eeprom.FlashBlkSz
Eeprom.FlashID
Eeprom.HostBusType
Eeprom.MFGWeek
Eeprom.MFGYear
Eeprom.MSBType
Eeprom.NumCPU
Eeprom.NumDaughterCard
Eeprom.NumDSPCores
Eeprom.NumSwitch
Eeprom.NumTrunk
Eeprom.Product
Eeprom.SerialNum
Eeprom.SoftwareCompatibility
Eeprom.SwitchType
Eeprom.TrunkType
EnableMonitor
Hdlc[x].Boot
Hdlc[x].RxTimeSlot
Hdlc[x].TxTimeSlot
Location.PCI.Bus
Location.PCI.Slot
Location.Type
MaxChannels
Name
NetworkInterface.T1E1[x].ConfigFile
NetworkInterface.T1E1[x].CRCMFMode
NetworkInterface.T1E1[x].D_Channel
NetworkInterface.T1E1[x].FrameType
NetworkInterface.T1E1[x].Impedance
NetworkInterface.T1E1[x].ISDN.D_Channel_Backup_Trunk
NetworkInterface.T1E1[x].ISDN.NFAS_Member[y].Board
NetworkInterface.T1E1[x].ISDN.NFAS_Member.Count
NetworkInterface.T1E1[x].ISDN.NFAS_Member[y].NAI
NetworkInterface.T1E1[x].ISDN.NFAS_Member[y].Trunk
NetworkInterface.T1E1[x].ISDN.NFASGroup
NetworkInterface.T1E1[x].Length
NetworkInterface.T1E1[x].LineCode
NetworkInterface.T1E1[x].SignalingType
NetworkInterface.T1E1[x].Type
Number
Products[x]
Resource[x].Definitions
Resource[x].Name
Resource[x].Size
Resource[x].StartDspTimeSlot
Resource[x].TimeSlotRange
Resource[x].TCPNum
Resource[x].TCPs
State
SwitchConnections
SwitchConnectMode
SwitchDriver.Name
TCPFiles[x]
Version.Major
Version.Minor

Appendix A Hardware Specifications

Specifications
Media Stream DSP Processing
PSTN Network Connectivity
Intra-chassis Connectivity
Software Environment
General
480 Port Configuration
Host Interface
H.110 Compliant Interface
Environment
Power Requirements for CG 6100C
CG 6100C Power Requirements with Daughterboard
CEPT E1 G.703 Telephony Interface
DSX-1 Telephony Interface
Compliance and Approvals
EMC
Safety
Telecom
International Approvals
EU R&TTE Statement
Standards

Appendix B DSP Resource Management

Introduction
Managed Resources
DSPs, DPMs, and DPFs
DSP Resources
Worst-Case Resource Management Calculation
Example
Resource Calculations
Overall Resource Requirements
Resource Management Keywords
Resource Definition String Syntax
DSP Files and Resource Definitions
Example: Configuring Available DSP Resources
Resource Definitions
Input and Output Slots
Resource Definition Examples
Example: All DPFs Running Exclusively
Example: All DPFs Running Simultaneously
Example: Some DPFs Running Simultaneously
Specifying Relationships Between DPFs
Example 1
Example 2
Natural Access Media Masks and Call Progress Masks
Echo Cancellation Restriction
Trunk Control Program Resource Usage
Debugging Resource Management
Using CG 6100C Debug Masks
Resource Management Board Errors
Debugging Resource Management With cgtrace
Default Functions Available for CG 6100C Boards
Custom Functions Available for CG 6100C Boards
DSP Files and MIPS Requirements
Echo Cancellation MIPS

Appendix C T1 and E1 Trunk Channels

Introduction
E1 Channels and Transmission Rates
Signaling
Channel Associated Signaling (CAS)
Common Channel Signaling (CCS)
Framing
T1 Framing
E1 Framing
Voice Encoding
Companding
AMI, Ones Density, and Zero Code Suppression

Appendix D Demonstration Programs and Utilities

Multiple Pool Demonstration Program: c6t2tivr
DSP Module Description Utility: f54info
Display Flash Memory and RAM: cg6ktool
CG Board Trace Utility: cgtrace


Table of Contents Index NMS Glossary Previous Page Next Page Version


Want to send us feedback on our documentation? Email: Tech_Pubs@nmss.com