Specifies the length (in feet) of the cable connecting the board to the telephone network so that the framer can adjust the pulse shape accordingly. Only applicable in T1 mode.
NetworkInterface.T1E1[x].Length = length
x = 0..15 (0-based trunk number or range of trunk numbers)
Read/Write
Integer
0
0 - 655 feet
NetworkInterface.T1E1[0..15].Length = 0
NetworkInterface.T1E1[x].ConfigFile, NetworkInterface.T1E1[x].CRCMFMode, NetworkInterface.T1E1[x].D_Channel, NetworkInterface.T1E1[x].FrameType, NetworkInterface.T1E1[x].Impedance, NetworkInterface.T1E1[x].LineCode, NetworkInterface.T1E1[x].SignalingType, NetworkInterface.T1E1[x].Type