Both the AG-T1 and the AG-E1 boards have LED indicators on the rear bracket. The following diagram indicates what each LED means:

Figure 15: AG-T1 and AG-E1 LEDs
To verify that the carrier signal is working properly, you can use one of the NMS line monitoring utilities:
These utilities have similar displays and command-line options. They are installed with the CT Access and AG Access software, and can be found in one of the following directories:
See Appendix B for complete documentation of these utilities.
To verify the carrier signal using t1stat or e1stat:
t1stat or e1stat
The utility displays information like the following:
T1 Line Status Display Natural MicroSystems Jan 7 1997
(Press F3 or ESC to exit)
AG-T1 # 0
-----------------------------------------------------------------
Start time: Thu Feb 20 15:58:56 1997
Elapsed Time: 0000:00:21
Board Status: RUNNING
T1a
-----------------------
Alarm: RED
Remote alarm: NONE
Errored seconds: 20
Failed seconds: 10
BPVs: 0
Slips: 0
Frame sync: *LOST*
The following should occur within a few seconds:
If any of the events listed here do not occur, check the cables and the connectors.
For more information about the LEDs on the rear bracket of the card, see section 4.2.