Static or noisy voice channels
|
· Check system's MVIP clock configuration. One and only board on MVIP bus must be bus master; all others should be slaved to the bus. Some boards, when configured as clock slaves, require that the board acting as bus clock master be booted first (i.e. require a stable clock on start up). AG Connect boards may act either as clock master or as clock slave. The AG Connect board clock mode is software configurable. For more information, refer to Section 2.4. If necessary, simplify your system by disconnecting any boards from the MVIP bus that are not directly relevant to the experiment you are performing.
· Ensure that all boards are using the same encoding law. For AG Connect boards, encoding law is established at installation time and applies system-wide. For AG resource boards, encode law is configured via the AG configuration file.
· Check that the PC (and external power supplies, if any) are properly grounded. See Section 2.5 and Section 2.6 for more information.
|