- In this example, the voice and signaling data from one operator station on an S Connect board are connected to DSP resources on an AG-8/DSP board. The AG-8/DSP board contains a switch block. The DSP resources are not nailed up to the bus; switch connections are required to connect the resources to the MVIP bus. The operator on timeslot 2 is connected to DSP resources on timeslot 5.
- On the S Connect board, the following connections are made:
MakeConnection( LOCAL:0:2 to MVIP:9:5 ) S Connect voice to H.100 bus CT_D9:5
MakeConnection( MVIP:8:5 to LOCAL:1:2 ) H.100 bus CT_D8:5 to S Connect voice
MakeConnection( LOCAL:2:2 to MVIP:11:5 ) S Connect signaling to CT_D11:5
MakeConnection( MVIP:10:5 to LOCAL:3:2 ) CT_D10:5 to S Connect signaling
- The following connections are made on the AG-8/DSP:
MakeConnection( LOCAL:4:5 to MVIP:8:5 ) DSP voice to H.100 bus CT_D8:5
MakeConnection( MVIP:9:5 to LOCAL:5:5 ) H.100 bus CT_D9:5 to DSP voice
MakeConnection( LOCAL:6:5 to MVIP:10:5 ) DSP signaling to H.100 bus CT_D10:5
MakeConnection( MVIP:11:5 to LOCAL:7:5 ) H.100 bus CT_D11:5 to DSP signaling

Figure 56. MVIP-95: Station Interface to Network Interface Connection