(Page 1 of 1 in this chapter) Version


Appendix C

Hardware Specifications


QX 2000/100-4L Board
Compliance and Regulatory Certification
QX 2000/80-4L Board
Compliance and Regulatory Certification

QX 2000/100-4L Board

General

Board Capacity

4 analog loop start interfaces.

TDM Bus

1 complete H.100 interface with MVIP-95 enhanced-compliant switching.

DSP Processing Power

1 Texas Instruments TMS320VC549 DSP at 100 MIPS.

Memory

64 Kword shared memory.

64 Kword program and data memory.

Software Development Kits

CT Access for Windows NT.

Host Interface

Electrical

PCI bus designed to PCI local bus specification Rev 2.1 for target boards.

Mechanical

Designed to the PCI local bus specification revision 2.1 for a long expansion card.

Bus Speed

33 MHz

Maximum Number Boards per System

8

Addresses/Interrupts

Address and interrupts automatically configured by PCI BIOS (no jumpers or switches).

MVIP Compliant Interface

· Flexible connectivity between analog trunks, DSPs, and H.100 bus.

· Switchable access to any of 4096 H.100 timeslots.

· H.100 clock master or clock slave (software selectable).

· Compatible with any MVIP compliant telephony interface.

Environment

Operating Temperature

0 to 50 degC

Storage Temperature

-20 to 70 degC

Humidity

5 to 80%, non-condensing

Power Requirements

+5 V < 0.8 Amp (300 mA typical)

+12 V < 100 mA

-12 V < 100 mA

Audio Signal Processing

Receive Range

-50 to +0 dBm (optional configurable AGC above nominal -44 dBm).

Transmit

Programmable (nominal -12 dBm).

Silence Detection

Programmable (nominal -44 dBm).

Sampling Rates

8 Ksamples/sec (telephone industry standard).

Speech

· 64 Kbps mu-law or A-law per ITU-T G.711

· 16, 24, 32, 40 Kbps ADPCM using ITU-T G.726 algorithm

· 16, 24, 32 Kbps NMS compatible ADPCM

· 32 Kbps VOX compatible ADPCM

· 8, 16 bit PCM 11, 22, 44 kHz

· 16 bit mono PCM 8 kHz

Audio Output

Frequency

300-3400 Hz

Impedance

100 ohms

Level

3 dB

Output Connector

3.5 mm stereo jack

Audio Input

Frequency

300-3400 Hz

Impedance

47 Kohms

Level

2 Vcc peak-to-peak

Output Connector

3.5 mm stereo jack

Local Phone Interface

Line Current

35 mA max for 400 ohm resistance

On/Off Hook Detection

Tone Dialing

DTMF Digits

0-9,*,#, and ABCD per ITU-T Q.23 and Q.24

Rate

Programmable (10 digits:sec nominal)*

Dialing Parameters

Software controllable*

Dialing Amplitude

Network compatible programmable range -33 dBm to 1 dBm*

Dial Tone Wait

Wait-for-dial-tone capability

Compliance and Regulatory Certification

Natural MicroSystems obtains board-level approvals certificates for supported countries. In some countries you will require, in addition to the approval obtained by NMS for the board and its associated software, a system level approval before connecting the system to the public network. To learn what approvals you require, contact the appropriate regulatory authority in the target country.
Type

Region

Refer to:

EMC

US and Canada

FCC Part 15, Subpart J, Class A

EU Countries

EN 55 022 (1994), class B
EN 55 082-1 (1992)

Other countries

The NMS website (www.nmss.com)

Safety

US and Canada

NRTL recognized to cUL (UL 1950, 3rd edition)

EU Countries

EN 60 950, 1992, with amendments 1, 2, 3, 4

Other countries

The NMS website (www.nmss.com)

Telecom

US

FCC Part 68

Canada

DOC CS-03

EU Countries

CTR21 (See note below)

Other countries

The NMS website (www.nmss.com)

Note: In Germany, Greece, and Portugal, your application must be designed so that the AG 2000 board seizes the phone line only with the intention to make a call. To satisfy the CTR21 regulatory requirements, the NMS document AG 2000 Loop Start and QX 2000 Loop Start Board Compliance Statements must be shipped with each of your products.

QX 2000/80-4L Board

General

Board Capacity

4 analog loop start interfaces.

TDM Bus

Features one complete MVIP-90 interface with MVIP-95 and MVIP-90 enhanced-compliant switching.

DSP Processing Power

1 Texas Instruments TMS320LC54x DSP at 80 MIPS.

Memory

64 Kword shared memory.

64 Kword program and data memory.

Software Development Kits

CT Access for Windows NT.

Host Interface

Electrical

PCI bus designed to PCI local bus specification Rev 2.1 for target boards.

Mechanical

Designed to the PCI local bus spec revision 2.1 for a long expansion card.

Bus Speed

33 MHz

Maximum Number Boards per System

8

Addresses/Interrupts

Address and interrupts automatically configured by PCI BIOS (no jumpers or switches).

MVIP Compliant Interface

· Flexible connectivity between analog trunks, DSPs, and MVIP bus.

· Switchable access to any of 512 MVIP timeslots.

· MVIP clock master or clock slave (software selectable).

· Compatible with any MVIP compliant telephony interface.

Environment

Operating Temperature

0 to 50 degC

Storage Temperature

-20 to 70 degC

Humidity

5 to 80%, non-condensing

Power Requirements

+5 V < 0.8 Amp (300 mA typical)

+12 V < 100 mA

-12 V < 100 mA

Audio Signal Processing

Receive Range

-50 to +0 dBm (optional configurable AGC above nominal -44 dBm)

Transmit

Programmable (nominal -12 dBm)

Silence Detection

Programmable (nominal -44 dBm)

Sampling Rates

8 Ksamples/sec (telephone industry standard)

Speech

· 64 Kbps mu-law or A-law per ITU-T G.711

· 16, 24, 32, 40 Kbps ADPCM using ITU-T G.726 algorithm

· 16, 24, 32 Kbps NMS compatible ADPCM

· 32 Kbps VOX compatible ADPCM

· 8, 16 bit PCM 11, 22, 44 kHz

· 16 bit mono PCM 8 kHz

Audio Output

Frequency

300-3400 Hz

Impedance

100 ohms

Level

3 dB

Output Connector

3.5 mm stereo jack

Audio Input

Frequency

300-3400 Hz

Impedance

47 Kohms

Level

2 Vcc peak-to-peak

Output Connector

3.5 mm stereo jack

Local Phone Interface

Line Current

35 mA max for 400 ohm resistance

On/Off Hook Detection

Tone Dialing

DTMF Digits

0-9,*,#, and ABCD per ITU-T Q.23 and Q.24

Rate

Programmable (10 digits:sec nominal)1

Dialing Parameters

Software controllable*

Dialing Amplitude

Network compatible programmable range -33 dBm to
1 dBm*

Dial Tone Wait

Wait-for-tone capability

Configurable by country, only when permitted by national regulations.

Compliance and Regulatory Certification

Natural MicroSystems obtains board-level approvals certificates for supported countries. In some countries you will require, in addition to the approval obtained by NMS for the board and its associated software, a system level approval before connecting the system to the public network. To learn what approvals you require, contact the appropriate regulatory authority in the target country.

Type

Region

Refer to:

EMC

US and Canada

FCC Part 15, Subpart J, Class A

EU Countries

EN 55022 (1994), class B
EN 55082-1 (1992)

Other countries

none

Safety

US and Canada

NRTL recognized to cUL (UL 1950, 3rd edition)

EU Countries

EN 60950 (1992), with amendments 1, 2, 3, 4

Other countries

none

Telecom

US

FCC Part 68

Canada

DOC CS-03

European Countries

France (B 11-23A), Germany (FTZ 223 ZV5), Italy (NET-4), U.K. (NET-4)

Other countries

none



(Page 1 of 1 in this chapter) Version


tech_support@nmss.com
Copyright © 1999, Natural MicroSystems, Inc. All rights reserved.