(Page 3 of 4 in this chapter)


Alphabetical Error Summary

The following table is an alphabetical listing of Switching service errors. All errors are 32 bits.

Error Name

Hex

Decimal

Description

SWIERR_CONNECTION_NOT_SUPPORTED

0x40011

262161

The switch block does not support the requested connection. There is a permanent limitation in the switch block that prevents the connection.

SWIERR_DEVICE_ERROR

0x40002

262146

The MVIP device driver encountered an error while using the services of another device driver.

SWIERR_DLL_INVALID_DEVICE

0x40001

262145

The Dynamic Link Library (DLL) could not find the requested device.

SWIERR_INTERNAL_CONFLICT

0x40010

262160

A switch component of a switch matrix conflicts with another switch component (the state of the switch matrix is ambiguous).

SWIERR_INVALID_CLOCK_PARM

0x40007

262151

Problem: The value of a clock configuration parameter is invalid.

Solution: Enter a valid value.

SWIERR_INVALID_COMMAND

0x40000

262144

The device driver does not support the requested operation.

SWIERR_INVALID_MINOR_SWITCH

0x4000B

262155

The value of the switch parameter is invalid.

SWIERR_INVALID_MODE

0x4000A

262154

Problem: The device driver does not support the setting of the mode of an output terminus to the mode specified (e.g., swiMakeFramedConnection is not supported in all hardware or by MVIP-90 drivers).

Solution: Enter a valid mode.

SWIERR_INVALID_PARAMETER

0x4000C

262156

Problem: The parameter needed by the called function is set to an invalid value.

Solution: Enter a valid value.

SWIERR_INVALID_SPEED

0x40008

262152

Problem: An invalid stream speed capacity was entered.

Solution: This functionality only works in MVIP-95. Enter one of the following acceptable speed values:

MVIP95_2MBPS_STREAM_SPEED
MVIP95_4MBPS_STREAM_SPEED
MVIP95_8MBPS_STREAM_SPEED

SWIERR_INVALID_STREAM

0x40004

262148

Problem: The value of stream in a terminus element is out of range.

Solution: Enter a valid value for stream in the terminus element.

SWIERR_INVALID_TIMESLOT

0x40005

262149

Problem: The value of timeslot in a terminus element is out of range.

Solution: Enter a valid value for timeslot in the terminus element.

SWIERR_MISSING_PARAMETER

0x40006

262150

An insufficient number of parameters were provided for the driver to complete the command.

SWIERR_MVIP_BUS_NOT_ENABLED

0x40012

262162

Problem: A switching command was called on a switch block on which the MVIP bus was not enabled.

Solution: Enable MVIP in the ag.cfg file for the switch block.

SWIERR_NO_PATH

0x4000E

262158

The device driver is unable to complete the connection because there is blocking or some other temporary switch limitation encountered.

SWIERR_NOT_CONFIGURABLE

0x40009

262153

The device does not support configuration of the parameters and/or values requested.

SWIERR_SWITCH_VERIFY_ERROR

0x4000F

262159

Verification of the switch operation failed.

SWIERR_UNSUPPORTED_MODE

0x4000D

262157

The mode is not supported by either the device driver or the hardware below the driver.



(Page 3 of 4 in this chapter)


tech_support@nmss.com