(Page 1 of 1 in this chapter)


Appendix C

Sample PPX Configuration File


Introduction

The following PPX configuration file includes a variety of NMS boards.

                       ppx.cfg
#
#         --- Point-to-Point Switching Service ---
#         ---        Configuration             ---
#
#   This file defines to the Point-to-Point Switching service
#   the available bus, timeslots, and switches it may use for
#   establishing connection paths.
#   
#   This configuration file contains example switch definitions
#   for the various NMS boards. Use this as a guide for
#   configuring the PPX service to your particular hardware
#   configuration.
#
#   Some Reminders:
#       - All switch numbers must be unique.
#       - The "DeviceNumber" is the board number established 
#         during H/W configuration, e.g., in "ag.cfg"
#       - The PPX service uses MVIP-95, not MVIP-90.
#    
#
[PPX]
Fabric
        Bus H100                        # H100 bus
            CTBUS:0..15:0..31
            CTBUS:16..23:0..63
            CTBUS:24..31:0..127
        End Bus
        Bus MVIP_90                     # MVIP-90 bus
            Bus H100 (CTBUS:0..15:0..31)
        End Bus
        Switch 0                        # AG-8  
            SwitchType = FMIC
            DeviceName = "agsw"
            DeviceNumber = 0
            Bus H100 (CTBUS:0..15:0..31) # on the MVIP-90 bus
            Inputs                  
                LOCAL:0..6(2):0..7      # line interfaces & DSP resources
            End Inputs
            Outputs                     
                LOCAL:1..7(2):0..7      # line interfaces & DSP resources
            End Outputs
        End Switch                           
        Switch 1                        # AG-T1
            SwitchType = FMIC
            DeviceName = "agsw"
            DeviceNumber = 3
            Bus MVIP_90 ()              # on the MVIP-90 bus
            Inputs                            
                LOCAL:0..6(2):0..23     # line interfaces & DSP resources
            End Inputs
            Outputs                        
                LOCAL:1..7(2):0..23     # line interfaces & DSP resources
            End Outputs
        End Switch
        Switch 2                        # AG Quad T
            SwitchType = HMIC
            DeviceName = "agsw"
            DeviceNumber = 2
            Bus H100 ()
            Inputs                       
                LOCAL:0..14(2):0..23    # Trunk
                LOCAL:16..18(2):0..127  # DSP
            End Inputs
            Outputs                           
                LOCAL:1..15(2):0..23    # Trunk
                LOCAL:17..19(2):0..127  # DSP
            End Outputs
        End Switch
        Switch 4                        # AG Dual T
            SwitchType = HMIC
            DeviceName = "agsw"
            DeviceNumber = 4
            Bus H100 ()
            Inputs                       
                LOCAL:0..14(2):0..23    # Trunk
                LOCAL:16..18(2):0..127  # DSP
            End Inputs
            Outputs                           
                LOCAL:1..15(2):0..23    # Trunk
                LOCAL:17..19(2):0..127  # DSP
            End Outputs
        End Switch
        Switch 5                        # Quad Connect T
            SwitchType = HMIC
            DeviceName = "agsw"
            DeviceNumber = 5
            Bus H100 ()
            Inputs                       
                LOCAL:0..14(2):0..23    # Trunk
            End Inputs
            Outputs                           
                LOCAL:1..15(2):0..23    # Trunk
            End Outputs
        End Switch
        #
        # AG-24 Resource Board (no physical switch)
        #
        # Note: In this example, the ag.cfg file contains the following
        #       definition of stream usage for the AG Resouce board.
        #
        #           MVIPSlot = 4:0..23
        #           MVIPSlot = 5:0..23   # signaling
        #
        #       But, the ag.cfg file uses the MVIP-90 standard for
        #       stream numbering; using MVIP-95, this translates into: 
        #        
        #            MVIP-90 stream 4 is MVIP-95 streams  8 and 9
        #            MVIP-90 stream 5 is MVIP-95 streams 10 and 11
        #                      
        Switch 6                        # AG-24  "virtual switch"
            Inputs                       
                Bus MVIP_90 (CTBUS:9..11(2):0..23) 
            End Inputs
            Outputs
                Bus MVIP_90 (CTBUS:8..10(2):0..23)
            End Outputs
        End Switch
        Switch 7                         # AG-30
            Inputs
                Bus MVIP_90 (CTBUS:4..6(2):0..29) # Connections nailed up
            End Inputs
            Outputs
                Bus MVIP_90 (CTBUS:5..7(2):0..29)
            End Outputs
        End Switch
        Switch 8                         # assigned as switch 1
            DeviceName = "mc1sw"         # MC1 board switch driver - mc1sw
            DeviceNumber = 0             # the number assigned during install.
            SwitchType = FMIC            # the switch on the MC1 is an FMIC
            Bus MVIP_90      ()          # MC1 is connected to the MVIP-90 bus
            Inputs
                MC1:0..42(2):0..63       # 22 input streams
            End Inputs
            Outputs
                MC1:1..7(2):0..63        # 4 output streams (1, 3, 5, 7)
            End Outputs
        End Switch
        Switch 9                         # WTI-8  
            SwitchType = FMIC
            DeviceName = "wti8sw"
            DeviceNumber = 0
            Bus MVIP_90 ()               # on the MVIP-90 bus
            Inputs                  
                LOCAL:0..2(2):0..7       # 8 line interfaces
            End Inputs
            Outputs                     
                LOCAL:1..3(2):0..7       # 8 line interfaces
            End Outputs
        End Switch                           
        Switch 10                        # T Connect-24
            SwitchType = FMIC
            DeviceName = "agcxsw"
            DeviceNumber = 0
            Bus MVIP_90 ()               # on the MVIP-90 bus
            Inputs                  
                LOCAL:0..2(2):0..23      # 24 line interfaces
            End Inputs
            Outputs                     
                LOCAL:1..3(2):0..23      # 24 line interfaces
            End Outputs
        End Switch                           
        Switch 11                        # S Connect-12
            SwitchType = FMIC
            DeviceName = "agcxsw"
            DeviceNumber = 1
            Bus MVIP_90 ()               # on the MVIP-90 bus
            Inputs                  
                LOCAL:0..2(2):0..11      # 12 station interfaces
            End Inputs
            Outputs                     
                LOCAL:1..3(2):0..11      # 12 station interfaces
            End Outputs
        End Switch                           
        Switch 12                        # ATI
            SwitchType = ATI
            DeviceName = "atsdrv"
            DeviceNumber = 0
            Bus H100 (CTBUS:0..15:0..31)
            Inputs                        
               LOCAL:0..2(2):0..23      # 24 Analog loop start lines; no DSPs
            End Inputs
            Outputs       
                LOCAL:1..3(2):0..23 
            End Outputs
        End Switch
        Switch 13                        # AG2000
             SwitchType = HMIC
             DeviceName = "agsw"
             DeviceNumber = 0
             Bus H100 ()
             Inputs
                LOCAL:0..2(2):0..7       # Trunk
                LOCAL:4..6(2):0..7       # DSP
             End Inputs
             Outputs
                LOCAL:1..3(2):0..7       # Trunk
                LOCAL:5..7(2):0..7       # DSP
             End Outputs
        End Switch
        Switch 14                        # AG4000
             SwitchType = HMIC
             DeviceName = "agsw"
             DeviceNumber = 1
             Bus H100 ()
             Inputs
                LOCAL:0..14(2):0..23     # Trunk (or ..29 for Es)
                LOCAL:16..18(2):0..127   # DSP
             End Inputs
             Outputs
                LOCAL:1..15(2):0..23     # Trunk (or ..29 for Es)
                LOCAL:17..19(2):0..127   # DSP
             End Outputs
        End Switch
        Switch 15                        # CompactPCI Quad
             SwitchType = HMIC
             DeviceName = "agsw"
             DeviceNumber = 1
             Bus H100 ()
             Inputs
                LOCAL:0..14(2):0..23     # Trunk (or ..29 for Es)
                LOCAL:16..18(2):0..127   # DSP
             End Inputs
             Outputs
                LOCAL:1..15(2):0..23     # Trunk (or ..29 for Es)
                LOCAL:17..19(2):0..127   # DSP
             End Outputs
        End Switch
        Switch 16                        # QX 2000/80-4L
             SwitchType = FMIC
             DeviceName = "qxsw"
             DeviceNumber = 1
             Bus MVIP_90 ()
             Inputs
                LOCAL:0..2(2):0..3       # Trunk
                LOCAL:4..6(2):0..3       # DSP
             End Inputs
             Outputs
                LOCAL:1..3(2):0..3       # Trunk
                LOCAL:5..7(2):0..3       # DSP
             End Outputs
        End Switch
        Switch 17                                # QX 2000/100-4L
             SwitchType = HMIC
             DeviceName = "qxsw"
             DeviceNumber = 1
             Bus H100 ()
             Inputs
                LOCAL:0..2(2):0..3               # Trunk
                LOCAL:4..6(2):0..3               # DSP
             End Inputs
             Outputs
                LOCAL:1..3(2):0..3               # Trunk
                LOCAL:5..7(2):0..3               # DSP
             End Outputs
        End Switch
             Connect
            0:local:0:0 to 0:local:5:0 QUAD
            0:local:0:2 to 0:local:5:2 QUAD NAILED
        End Connect
End Fabric



(Page 1 of 1 in this chapter)


tech_support@nmss.com