(Page 22 of 46 in this chapter)


EnableMVIP

Syntax

EnableMVIP = YES | NO

Description

Specifies whether the current board(s) should be electrically connected to the MVIP-90 bus, H.100, or H.110 bus.

If EnableMVIP = NO:

If EnableMVIP = YES:

The EnableMVIP default values for the AG-T1, AG-E1, AG Quad, AG 4000, AG 2000, CompactPCI AG Quad, and AG-8 depend on the values of the ClockRef, DriveSec8K, and MVIPslot statements. If ClockRef = MVIP or SEC8K, DriveSec8K = NETx, or if MVIPslot is specified, then EnableMVIP = YES. Otherwise, EnableMVIP = NO.

The default, and only valid value, for AG-24/30/48/60 boards is YES.

Example

EnableMVIP = YES

See Also

ClockRef, DriveSec8K, MVIPslot