(Page 30 of 46 in this chapter)


LineType

Syntax

LineType[line [..endline]] = LOOPSTART | LOOP | E&M | E&M1A | DID

Description

This statement configures one or more analog telephone line interfaces on an AG-8. If no line number is specified, the statement applies to all line interfaces.

Each line interface device has a default line type: the default for the LS interface is LOOPSTART and the default for the DID/E&M interface is DID.

Example

LineType = LOOP # Configures all 8 lines
# as loop start lines

LineType 0..7 = E&M # Configures lines 0-7
# as E&M lines



(Page 30 of 46 in this chapter)