(Page 33 of 46 in this chapter)
MVIPslot
Syntax
MVIPslot = stream: timeslot[..endslot][,idlecode]
Description
- Specifies an MVIP timeslot or range of MVIP timeslots driven by the AG-24/30/48/60 board's DSP resources. It optionally specifies the bit pattern transmitted on the MVIP timeslot(s) when idle.
- The
MVIPslot statement uses the MVIP-90 naming convention for bus streams and timeslots.
- Each MVIP timeslot can be driven by only one board. Therefore, this statement must not be in the
Common section. If used, it must be included in each board-specific section with different values for each AG board.
- This statement is not typically used for AG-8, AG-T1, or AG-E1 boards. However, it can be used to configure these boards as MVIP resource boards. In this case, the line interface(s) will not be connected.
- The idle code, if included, must be specified with no space to the left of the comma. If an idle code is not specified here, then the
IdleCode statement that applies to the current board is used.
Note: The MVIPslot statement is required for configurations with
AG-24/30/48/60 boards. In these configurations, you must nail up DSP resources on the board to the MVIP bus with MVIP-90 terms. For more information about this process, refer to the
AG-24/30/48/64 Installation and Developer's Manual.
- The
MVIPslot statement is invalid for boards which support the MVIP-95 device driver only (such as the AG Quad board).
Example
MVIPslot = 6:0..23,0x7F
MVIPslot = 6:0..23
See Also
IdleCode
(Page 33 of 46 in this chapter)
tech_support@nmss.com
Copyright © 1999, Natural MicroSystems, Inc. All rights
reserved.