Version

# T1 Example
# Timing Configurations:
#
CLOCK NETA
SEC8K NONE
#
# TX Port MVIP Stream Start Channel Count Direction
# ------- ----------- ------------- ----- ---------
Port1 Stream0 Channel0 Count1 Standard
Port2 Stream1 Channel0 Count56 Standard
Port3 Stream2 Channel0 Count1 Standard
Port4 T1A Channel0 Count1 Standard
#
# T1 Framing Encoding Buildout Robbed Bit Loop Master
# -- ------- -------- -------- ---------- -----------
T1A D4 B7ZS 0 TRUE FALSE
T1B ESF B8ZS 0 FALSE FALSE
# E1 Example
# Timing Configurations:
#
CLOCK NETA
SEC8K NONE
#
# TX Port MVIP Stream Start Channel Count Direction
# ------- ----------- ------------- ----- ---------
Port1 Stream0 Channel0 Count1 Standard
Port2 Stream1 Channel0 Count56 Standard
Port3 Stream2 Channel0 Count1 Standard
Port4 E1B Channel1 Count1 Standard
#
# E1 Framing Encoding Buildout Robbed Bit Loop Master
# -- ------- -------- -------- ---------- -----------
E1A CAS HDB3 4 TRUE FALSE
E1B CAS HDB3 4 FALSE FALSE

|
NOZCS
|
[T1 or E1] AMI encoding with no zero code suppression.
|
|
B7ZS
|
[T1] Bit Seven Zero Stuffing.
|
|
B8ZS
|
[T1] Bipolar Eight Zero Substitution.
|
|
HDB3
|
[E1] High Density Bipolar (order 3) encoding.
|
|
T1
|
E1
|
|---|---|
|
0: 0-133 Feet
|
|
|
1: 133-266 Feet
|
|
|
|
4: 120 Ohm Normal With Protection Resistors [This value is the default for E1]
|
|
2: 266-399 Feet
|
|
|
3: 399-533 Feet
|
|
|
4: 533-655 Feet
|
|


STANDARD: MVIP H.100
Stream 0 DSo0 = input Stream 0
DSi0 = output (Stream 1)
Stream 1 DSo1 = input Stream 2
DSi1 = output (Stream 3)
REVERSE: MVIP H.100
Stream 0 DSo0 = output Stream 0
DSi0 = input (Stream 1)
Stream 1 DSo0 = output Stream 2
DSi1 = input (Stream 3)
Note: Reverse is only applicable to MVIP/H.100/H.110 channels; T1/E1 channels should always be specified as Standard.