(Page 8 of 22 in this chapter) Version
TxSampleInput
Description
- Retrieves the most recent input byte received on a particular switch input stream/timeslot.
Prototype
- short TxSampleInput (short handle,
STREAM_T iStream,
TIMESLOT_T iTimeslot,
DATA_T iSample)
- handle TX board number.
- iStream Input stream number. For MVIP-90, must be between 0 and 15 for MVIP, 16 for T1-A, and 18 for T1-B. For MVIP-95, must be between 0 and 31 for H.100/H.110, 40 for T1-A, and 41 for T1-B.
- iTimeslot Input timeslot number. For MVIP-90, must be between 0 and 31. For MVIP-95, must be between 0 and 127 for H.100/H.110, and between 0 and 31 for T1 interfaces.
- iSample Address where the current value input from the stream/timeslot is returned to caller.
Return Values
Details
- The data returned by TxSampleInput may change every 125 microseconds, and thus may not be of much relevance by the time the application gets the data.