(Page 11 of 14 in this chapter) Version


Flow Control Indication

Direction

MTP 2 -> Layer 3

Description

The FLOW CONTROL INDICATION notifies the application (layer 3) that a congestion condition (available buffer memory below the threshold) has started or ended on a physical link.

Format

Service User ID Application's reference number for this link (from BIND REQUEST)

Action The condition being reported. Possible values are:

   0  Congestion started
   1  Congestion ended