Field Name
|
Type/Unit
|
Default
|
Description
|
|---|
|
cleardownflag
|
mask
|
1
|
Selects whether to run the cleardown tone detector in the conversation state.
Value Definition 1 Cleardown enabled 0 Not enabled
|
|
qualloopoff
|
ms
|
10
|
Minimum duration of loop current interruption before a hang-up will be recognized.
|
|
ringdetectmode
|
mask
|
0
|
Selects whether the ring detector is voltage-sensitive or frequency-selective.
Value Definition 0 Voltage-sensitive 1 Frequency-selective
|
|
qualringon
|
ms
|
6
|
For voltage-sensitive ring detection, the minimum duration of detected voltage to be recognized as the start of a ringing signal.
|
|
qualringoff
|
ms
|
100
|
For voltage-sensitive ring detection, the minimum duration of loss of detected voltage to be recognized as the end of a ringing signal.
|
|
freqringlow
|
Hz
|
16
|
For frequency-selective ring detection, the minimum frequency recognized.
|
|
freqringhigh
|
Hz
|
54
|
For frequency-selective ring detection, the maximum frequency recognized.
|
|
freqringperiods
|
count
|
4
|
For frequency-selective ring detection, number of periods of the ring frequency needed to qualify. Range is 1-8.
|
|
freqdeglitchtime
|
count
|
26
|
For frequency-selective ring detection, deglitch time in 1/8 ms. Range is 2-80 (.25 to 10 ms).
|
|
freqtolerance
|
percent
|
10
|
For frequency-selective ring detection, frequency tolerance in percent.
|
|
ringsigmintime
|
ms
|
100
|
The minimum duration of a detected ring signal before the ring signal is considered valid.
|
|
ringsigmaxtime
|
ms
|
3000
|
The maximum duration of a detected incoming ringing signal before the ringing is considered to be invalidly long.
|
|
interringmaxtime
|
ms
|
8000
|
The maximum length of an incoming ring period (on time + off time) that can elapse before the call is considered to be abandoned.
|
|
numrings
|
count
|
0
|
Number of rings to detect for an incoming cal.: Value Definition 0 1st ring begin 1 1st ring end n after n rings Note that if caller ID is enabled (cidsupport = 1) then the incoming call is reported after at least one ring.
|
|
dialtonewaittime
|
ms
|
5000
|
For outgoing calls, the maximum time to wait for initial dial tone.
|
|
dialtonemintime
|
ms
|
1000
|
For outgoing calls, the minimum duration of non-precise dial tone required before dialing will begin.
Set this to 0 to disable non-precise dial tone detection. (Precise dial tone detection is controlled by ADI_START_PARMS.)
|
|
nodialtoneaction
|
integer
|
0
|
Selects what to do if no dial tone detected.
Value Definition 0 Hang up and abandon the call 1 Proceed to dial anyway 2 Generate an incoming call event
|
|
xfersupport
|
mask
|
1
|
Flag to select whether PBX transfer is allowed.
Value Definition 0 Transfer commands are disabled 1 Transfer commands are allowed
|
|
cidsupport
|
mask
|
0
|
Flag to enable caller ID detection.
Value Definition 0 No caller ID detection 1 Caller ID detection enabled
For AG boards, the AG configuration file must include the DSP file adsir.dsp when caller ID is enabled.
|
|
reversalmode
|
integer
|
0
|
Selects a loop current reversal detection mode for the AG 2000 board.
Value Definition 0 Disable detection 1 Reversal indicates remote answer 2 Reversal indicates remote hang up
3 Reversal indicates answer and hang up
|
|
releaseguardtime
|
ms
|
1000
|
If the host specifies to place a call immediately after releasing a call, the line is not taken off-hook until this time has elapsed. This ensures that the CO considers the line idle.
|
- CIDtype
|
integer
|
- 0
|
Type of Caller ID protocol, if CID is enabled.
Value Definition 0 BellCore CID Protocol 1 NTT Japan CID Protocol 2 ETSI Ringing Pulse Alerting Signal CID Protocol
|
- CIDmaxwaittime
|
ms
|
- 0
|
Maximum time to wait for Caller ID to arrive before concluding the caller has hung up (if CID is enabled).
|
- xferstring
|
String[6]
|
"!;"
|
Prefix of feature code for transfer operation. The default string "!;" generates a flash hook, then waits for a dialtone.
|
- connstring
|
String
|
- "!"
|
Dial string for reconnect.
|
- CIDalertmaxtime
|
ms
|
- 0
|
Maximum duration of an alert signal in Caller ID protocol (if CID is enabled).
|
- qualreversal
|
ms
|
- 200
|
Qualification time for loop current reversal event on the AG 2000 board.
|
- polaranswertime
|
ms
|
- 0
|
Wait time after going off-hook answering a call before you start detecting the loop current polarity reversal on far-end disconnect (if reversal mode = 2 or 3).
|
- polardialtime
|
ms
|
- 0
|
Wait time after dialing before starting the loop current polarity reversal detection (if reversal mode = 1 or 3).
|
- relaytype
|
integer
|
- 0
|
Obsolete. Kept for applications runtime compatibility.
|
- CIDminmarktime
|
ms
|
- 100
|
Minimum duration of the "mark" signal of the caller ID protocol that is interpreted as such.
|