hmiShutdown
Description
- Requests the local HMI service to shutdown gracefully, but without initiating a "go backup" message if active.
Prototype
- DWORD hmiShutdown (CTAHD ctahd)
- ctahd CT Access handle from a previous successful call to ctaOpenServices.
Return Values
Details
- This request causes the HMI to shutdown immediately. If the board being shut down is the primary board, no HMI backup request is performed, since shutting down does not change the status of the board. If the user wishes an immediate switchover prior to shutdown of the primary board, an HMI backup request should be issued before the shutdown request and an HMI primary request should be issued for the other board.
- All applications registered for unsolicited status events are notified of the pending shutdown with a HMI _EVN_SERVICE_DOWN event.