Table of Contents Index NMS Glossary Previous Page Next Page (Page 19 of 41 in this chapter) Version


slotStatus

Syntax

Integer

Access

Read-only

OID

p.3.1.1.4.n.m, where n is the index of this segment in the Bus Segment table, and m is the index of the slot in this segment.

Description

The Hot Swap status, from the Hot Swap state diagram. Acceptable values are:
Value

Status

1

Online.

2

OnLine Pending. The board coming online is in progress.

3

Failed.

4

Offline. The board is turned off, and can be extracted.

5

Offline Pending. Waiting for activity to stop, which can be time consuming.

6

Extracted.

For CT Access 3.x, acceptable values are:
Value

State

Description

1

P0

Board is not present in the slot.

2

S0

Board is present, but not configured for Hot Swap.

3

S1

Hot Swap device instance is not started.

4

S1F

The Hot Swap device instance failed to start.

5

S1I

The Hot Swap device instance is started, but the board is not prepared for use (insertion is in progress).

6

S1B

Board is being prepared (insertion is in progress).

7

S1BF

Board preparation failed.

8

S2

Board is ready.

9

S2R

Extraction in progress.

Configuration

Not applicable.



Table of Contents Index NMS Glossary Previous Page Next Page (Page 19 of 41 in this chapter) Version


Want to send us feedback on our documentation? Email: Tech_Pubs@nmss.com