(Page 19 of 41 in this chapter)
Version
slotStatus
Syntax
Integer
Access
Read-only
OID
p
.3.1.1.4.
n
.
m
, where
n
is the index of this segment in the Bus Segment table, and
m
is the index of the slot in this segment.
Description
The Hot Swap status, from the Hot Swap state diagram. Acceptable values are:
Value
Status
1
Online.
2
OnLine Pending. The board coming online is in progress.
3
Failed.
4
Offline. The board is turned off, and can be extracted.
5
Offline Pending. Waiting for activity to stop, which can be time consuming.
6
Extracted.
For CT Access 3.x, acceptable values are:
Value
State
Description
1
P0
Board is not present in the slot.
2
S0
Board is present, but not configured for Hot Swap.
3
S1
Hot Swap device instance is not started.
4
S1F
The Hot Swap device instance failed to start.
5
S1I
The Hot Swap device instance is started, but the board is not prepared for use (insertion is in progress).
6
S1B
Board is being prepared (insertion is in progress).
7
S1BF
Board preparation failed.
8
S2
Board is ready.
9
S2R
Extraction in progress.
Configuration
Not applicable.
(Page 19 of 41 in this chapter)