(Page 12 of 39 in this chapter)
Version
dsx1LoopbackConfig
Syntax
Integer
Access
Read-write
OID
p
.6.1.9.
n
, where
n
= the index number of the DS1 interface.
Description
Represents the loopback configuration of the DS1 interface. The Trunk agent will return
badValue
in response to a requested loopback state that the interface does not support. Valid types for RFC 2495 are:
Type
Value
Description
dsx1NoLoop
1
Not in the loopback state. A device that is not capable of performing a loopback on the interface will always return this value.
dsx1PayloadLoop
2
The received signal at this interface is looped through the device. Typically, the received signal is looped back for re-transmission after it has passed through the device's framing function.
dsx1LineLoop
3
The received signal at this interface does not go through the device.
dsx1OtherLoop
4
Loopbacks that are not defined.
Note:
The agent will only return
dsx1NoLoop
(1). Boards from Natural MicroSystems do not support loopback.
Configuration
Not applicable.
(Page 12 of 39 in this chapter)
Version
Want to send us feedback on our documentation? Email: