(Page 27 of 39 in this chapter) Version
dsx1CurrentESs
Syntax
- Gauge
Access
- Read-only
OID
- p.7.1.2.n, where n = the index number of the DS1 interface.
Description
- Number of Errored Seconds.
- For ESF and E1-CRC links, an Errored Second is a second with one or more Path Code Violations, OR one or more Out of Frame defects, OR one or more Controlled Slip events, OR a detected AIS defect.
- For D4 and E1-noCRC links, the presence of Bipolar Violations also triggers an Errored Second.
- This value is not incremented during an Unavailable Second.
Configuration
- Not applicable.