(Page 28 of 39 in this chapter) Version
dsx1CurrentSESs
Syntax
- Gauge
Access
- Read-only
OID
- p.7.1.3.n, where n = the index number of the DS1 interface.
Description
- Number of Severely Errored Seconds.
- A Severely Errored Second for ESF signals is a second with 320 or more Path Code Violation Error Events, or one or more Out of Frame defects, or a detected AIS defect.
- For E1-CRC signals, a Severely Errored Second is a second with 832 or more Path Code Violation error events, or one or more Out of Frame defects.
- For E1-no CRC signals, a Severely Errored Second is a 2048 Line Code Violations or more.
- For D4 signals, a Severely Errored Second is a count of one-second intervals with Framing Error events, or an OOFdefect, OR 1544 Line Code Violations or more.
- Controlled slips are not included in this parameter.
- This value is not incremented during an Unavailable Second.
Configuration
- Not applicable.