dsx1CurrentCSSs

Syntax

Gauge

Access

Read-only

OID

p.7.1.6.n, where n = the index number of the DS1 interface.

Description

Number of Controlled Slip Seconds.

A Controlled Slip Second is a one-second interval containing one or more controlled slips.

A Controlled Slip is the replication or deletion of the payload bits of a DS1 frame. A Controlled Slip may occur when there is a difference between the timing of a synchronous receiving terminal and the received signal. A Controlled Slip does not cause an Out of Frame error.

Configuration

Not applicable.