NMS Logo

CG 6000C Installation and Developer's Manual

P/N 6745-13
Version


Table of Contents Index NMS Glossary Previous Page Next Page Version


Table of Contents

1 Overview of the CG 6000C Board

1.1 Overview
1.2 Introduction
1.3 CG 6000C Board Features
1.3.1 Universal Ports
1.4 Software Requirements
1.4.1 OAM
CG Board Plug-In
1.4.2 OAM Configuration Files
1.4.3 Runtime Software
1.4.4 Trunk Control Programs (TCPs)
1.4.5 CT Access
1.5 NMS Fusion and the CG 6000C Board

2 Installing the Hardware

2.1 Introduction
2.2 Installation Summary
2.3 System Requirements
2.4 Installing the Hardware
2.4.1 Setting the Board
2.4.2 Sample Trunk Configurations
2.4.3 Changing the DIP Switch Setting
E1 75 Ohm Configuration
E1 120 Ohm or T1 Configuration
2.4.4 Installing the Board
2.4.5 Keying Information
2.5 Trunk Connections and Ethernet Connections
2.6 Connecting a CG 6000C Board to a T1 Network
2.6.1 Cable Requirements
2.6.2 Ordering T1 Service
2.7 Connecting a CG 6000C Board to an E1 Network
2.7.1 Connecting a CG 6000C to an E1 120 Ohm
2.7.2 Connecting a CG 6000C to an E1 75 Ohm
2.8 Loopback Configuration
2.9 Connecting a CG 6000C Board to an Ethernet Connection

3 Configuring the Board

3.1 Introduction
3.2 Adding CG Configurations to the OAM Database
3.3 Configuring and Starting the System with oamsys
3.3.1 Creating a System Configuration File for oamsys
Sample System Configuration File
3.3.2 Running oamsys
3.4 Changing Configuration Parameter Settings
3.4.1 Board Keyword Files
3.4.2 Specifying Configuration File Locations
3.5 Configuring Board Clocking
3.5.1 Clocking References
3.5.2 Fallback Clocking
3.5.3 Configuring CT Bus Clocks with CG Keywords
Configuring the Primary Clock Master
Configuring the Secondary Clock Master
Configuring Clock Slaves
Configuring Standalone Boards
3.5.4 Example: Multiple Board System
3.5.5 CG 6000C Clocking Rules and Restrictions
Clocking Priority in Mixed Board Systems
3.6 Configuring Ethernet Connections
3.6.1 Setting up the Ethernet Connections
IP Addresses
Static IP Routes
Example
3.6.2 Ethernet Redundancy Mode
Example
3.6.3 Multiple Subnet Mode
Example
3.7 Sample Board Keyword Files
E1 Configuration with ISDN
No Call Control Configuration
3.8 Using DSP Resource Management Keywords
3.8.1 Resource Management Keywords
3.8.2 Resource Definition String Syntax
3.8.3 DSP Files
Example: Configuring Available DSP Resources
3.8.4 Resource Definitions
Example: All DPFs Running Exclusively
Example: All DPFs Execute Simultaneously
3.8.5 Specifying Conditional Relationships Between DSP Functions
Example 1
Example 2
3.8.6 Echo Cancellation Restrictions

4 Verifying the Installation

4.1 Introduction
4.2 Status Indicator LEDs
4.2.1 Trunk LEDs
4.2.2 Ethernet LEDs
4.3 Verifying That the Board is Installed Correctly
4.4 Verifying That the Board is Working Correctly
4.5 Demonstration Programs

5 CG 6000C Switching

5.1 Introduction
5.2 CG 6000C Switch Model
5.2.1 Lucent T8105 Switch Blocking
5.3 T1 Trunk Channels and Local Timeslots
5.3.1 T1 Channels/Timeslots for Channel Associated Signaling
5.3.2 T1 Channels/Timeslots for Common Channel Signaling
5.3.3 T1 Channels and Timeslots for RAW Mode
5.4 E1 Trunk Channels and Timeslots
5.4.1 E1 Signaling for Channel Associated Signaling
5.4.2 E1 Signaling/Timeslots for Common Channel Signaling
5.4.3 E1 Channels and Timeslots for RAW Mode
5.5 Default Connections for Standalone Board

6 CG Keyword Reference

6.1 Introduction
6.2 Keyword Types
6.2.1 Setting Keyword Values
6.2.2 Retrieving Keyword Values
6.3 Summary of Editable Keywords
6.4 Summary of Informational Keywords
6.5 Summary of Plug-in Keywords
6.6 Alphabetical Keyword Reference AutoStart 118

AutoStop 119

Boards[x] 120

BootDiagnosticLevel 121

BootDiagnosticMask 122

Buffer[x].Size 123

Clocking.HBus.AutoFallBack 124

Clocking.HBus.ClockMode 126

Clocking.HBus.ClockSource 127

Clocking.HBus.ClockSourceNetwork 129

Clocking.HBus.FallBackClockSource 130

Clocking.HBus.FallBackNetwork 132

Clocking.HBus.NetRef2Source 133

Clocking.HBus.NetRef2SourceNetwork 134

Clocking.HBus.NetRef2Speed 135

Clocking.HBus.NetRefSource 136

Clocking.HBus.NetRefSourceNetwork 137

Clocking.HBus.NetRefSpeed 138

Clocking.HBus.SClockSpeed 139

Clocking.HBus.Segment 140

DebugMask 141

DetectedBoards[x] 142

DLMFiles[x] 143

Driver.BoardId 144

Driver.Name 145

DSP.C5x[x].Files[y] 146

DSP.C5X[x].Image 149

DSP.C5x[x].Libs[y] 150

DSP.C5x[x].Os 151

DSP.C5x[x].XLaw 152

DSPStream.SignalIdleCode[x] 153

DSPStream.SlotCount 154

DSPStream.VoiceIdleCode[x] 155

Eeprom.AssemblyRevision 156

Eeprom.ATETestBit 157

Eeprom.DSPExtClk 158

Eeprom.DSPSpeed 159

Eeprom.DSPType 160

Eeprom.EthernetType 161

Eeprom.Family 162

Eeprom.FlashBlkSz 163

Eeprom.FlashID 164

Eeprom.HostBusType 165

Eeprom.MFGWeek 166

Eeprom.MFGYear 167

Eeprom.MSBType 168

Eeprom.NumCPU 169

Eeprom.NumDaughterCard 170

Eeprom.NumDSPCores 171

Eeprom.NumEthernet 172

Eeprom.NumSwitch 173

Eeprom.NumTrunk 174

Eeprom.Product 175

Eeprom.SerialNum 176

Eeprom.SoftwareCompatibility 177

Eeprom.SwitchType 178

Eeprom.TrunkType 179

EnableMonitor 180

Hdlc[x].Boot 181

Hdlc[x].Comet.RxTimeSlot 182

Hdlc[x]..Comet.TxTimeSlot 183

IPC.AddRoute[x].DestinationAddress 184

IPC.AddRoute[x].GatewayAddress 185

IPC.AddRoute[x].Interface 186

IPC.AddRoute[x].Mask 187

Location.PCI.Bus 188

Location.PCI.Slot 189

Location.Type 190

MaxChannels 191

Name 192

NetworkInterface.T1E1[x].ConfigFile 193

NetworkInterface.T1E1[x].CRCMFMode 194

NetworkInterface.T1E1[x].D_Channel 195

NetworkInterface.T1E1[x].FrameType 196

NetworkInterface.T1E1[x].Impedance 197

NetworkInterface.T1E1[x].ISDN.D_Channel_Backup_Trunk 198

NetworkInterface.T1E1[x].ISDN.NFAS_Member[y].Board 199

NetworkInterface.T1E1[x].ISDN.NFAS_Member.Count 200

NetworkInterface.T1E1[x].ISDN.NFAS_Member[y].NAI 201

NetworkInterface.T1E1[x].ISDN.NFAS_Member[y].Trunk 202

NetworkInterface.T1E1[x].ISDN.NFASGroup 203

NetworkInterface.T1E1[x].Length 204

NetworkInterface.T1E1[x].LineCode 205

NetworkInterface.T1E1[x].SignalingType 207

NetworkInterface.T1E1[x].Type 209

Number 210

Products[x] 211

Resource[x].Definitions 212

Resource[x].Name 215

Resource[x].Size 216

Resource[x].TCPNum 217

Resource[x].TCPs 218

State 219

SwitchConnections 220

SwitchConnectMode 221

SwitchDriver.Name 222

TCPFiles[x] 223

Version.Major 224

Version.Minor 225

Appendix A Hardware Specifications

Specifications
IP Network Connectivity
Media Stream DSP Processing
PSTN Network Connectivity
Intra-chassis Connectivity
Software Environment
General
120 Port Configuration
Host Interface
H.110 Compliant Interface
Environment
Power Requirements for CG 6000C
CEPT E1 G.703 Telephony Interface
DSX-1 Telephony Interface
Compliance and Approvals
EMC
Safety
Telecom
Standards

Appendix B DSP Resource Management

Introduction
Managed Resources
DSPs, DPMS, and DPFs
DSP Resources
Worst-Case Resource Management Calculation
Example
Resource Calculations
Overall Resource Requirements
Resource Management Keywords
Resource Definition String Syntax
DSP Files and Resource Definitions
Example: Configuring Available DSP Resources
Resource Definitions
Input and Output Slots
Resource Definition Examples
Example: All DPFs Running Exclusively
Example: All DPFs Running Simultaneously
Example: Some DPFs Running Simultaneously
Specifying Conditional Relationships Between DPFs
Example 1
Example 2
CT Access Media Masks and Call Progress Masks
Echo Cancellation Restriction
Trunk Control Program Resource Usage
Debugging Resource Management
Using CG 6000C Debug Masks
Resource Management Board Errors
Debugging Resource Management with cgtrace
CG 6000C Board DSP Resource Usage
Default Functions Available for CG 6000C Boards
Custom Functions Available for CG 6000C Boards
DSP Files and MIPS Requirements

Appendix C T1 and E1 Trunk Channels

Introduction
Channels and Transmission Rates
Signaling
Channel Associated Signaling (CAS)
Common Channel Signaling (CCS)
Framing
T1 Framing
E1 Framing
Voice Encoding
Companding
AMI, Ones Density, and Zero Code Suppression

Appendix D Utilities

DSP Module Description Utility: f54info
Display Flash memory, EEPROM, and RAM: cg6ktool
CG Board Trace Utility: cgtrace


Table of Contents Index NMS Glossary Previous Page Next Page Version


Want to send us feedback on our documentation? Email: Tech_Pubs@nmss.com
Copyright © 2000, Natural MicroSystems, Inc. All rights reserved.