Table of Contents Index NMS Glossary Previous Page Next Page (Page 11 of 111 in this chapter) Version


Clocking.HBus.ClockSourceNetwork

Syntax

Clocking.HBus.ClockSourceNetwork = networknum

Note: For more information about setting up CT bus clocking, and about the rules and restrictions that apply to setting up clocking with CG 6000C boards, refer to Section 3.5.

Access

Read/Write

Type

Integer

Default

1

Allowed Values

1 | 2 | 3 | 4 (1-based trunk number)

Example

Clocking.HBus.ClockSourceNetwork = 1

Description

Indicates the number of a trunk that the board uses as an external network timing reference for its internal clock.

The board must have multiple external network connections and the Clocking.HBus.FallBackClockSource keyword must be set to NETWORK for this to take effect.

When using Clocking.HBus.FallBackNetwork, the NetworkInterface.T1E1[x].Type keyword must be configured to either T1 or E1 and not to NONE.

Note: The Clocking.HBus.FallBackNetwork entry is a one based number, while the x entry in the NetworkInterface.T1E1[x].Type keyword is a zero based number

If the Clocking.HBus.ClockSource keyword is not set to NETWORK, this keyword is ignored.

See Also

Clocking.HBus.ClockSource



Table of Contents Index NMS Glossary Previous Page Next Page (Page 11 of 111 in this chapter) Version