NetworkInterface.T1E1[x].Type

Syntax

NetworkInterface.T1E1[x].Type = trunk_type

x = 0..3 (0-based trunk number or range of trunk numbers)

Access

Read/Write

Type

String

Default

E1

Allowed Values

T1 | E1 | NONE

Example

NetworkInterface.T1E1[0..3].Type = E1

Description

Specifies the trunk type for each trunk on the board. The default is E1 for CG 6000C boards.

Note: This setting must be the same for all active trunks. Unused trunks must be configured as NONE.

See Also

NetworkInterface.T1E1[x].ConfigFile, NetworkInterface.T1E1[x].CRCMFMode, NetworkInterface.T1E1[x].D_Channel, NetworkInterface.T1E1[x].FrameType, NetworkInterface.T1E1[x].Impedance, NetworkInterface.T1E1[x].Length, NetworkInterface.T1E1[x].LineCode, NetworkInterface.T1E1[x].SignalingType